Sargent 10X Line

Sargent 10X Line

Sargent 10X Line

Sep 30
2022

10X Line - Upgrade Your Opening

Commercial buildings of all kinds may vary in their size, use and design, but all are heavily influenced by three major trends today:

Adherence to the latest building code requirements, regardless of age, is more strictly enforced.
Management of facilities is growing more complex due to increasing number and sophistication of building systems and materials, along with the variety of users and the multiple security levels each requires.

Users’ expectations have risen, driving demand for safe and easier access to spaces (in and outside of buildings), coupled with more aggressive security measures. And on the heels of a pandemic, reduction of germ transmission is a high expectation on nearly every occupant’s list.

The SARGENT 10X Line bored lock is engineered to secure and protect high-traffic, high-abuse spaces. It doesn't simply meet ANSI/BHMA Grade 1 performance standards for durability, strength and performance, it exceeds them - by as much as 20 times. That means occupants will experience reliable performance throughout its lifecycle.

10X Line Cylindrical Lever Locks

Applications

  • Heavy duty commercial and institutional interior and exterior doors
  • Offices
  • Schools/Universities
  • Hospitals
  • Manufacturing facilities
  • Government

ANSI/BHMA: Certified ANSI/BHMA A156.2 (2017) Series 4000 — Grade 1, Certified ANSI/BHMA A156.41

UL/cUL: UL/cUL listed to US and Canadian safety standards for 3 hour doors up to 4' x 10' (double doors require 41- option)

NFPA 80: Conforms for life safety and property protection, Standard for Fire Doors and Other Opening Protectives

Positive Pressure: Meets ANSI/UL 10C, Positive Pressure Fire Test of Door Assemblies

ADA: All levers conform to ADA clear opening width requirements of ANSI A117.1

California State Reference Code (Formerly Title 19, California State Fire Marshal Standard): All levers with returns comply; levers return to within 1/2" (13mm) of door face

Windstorm/Hurricane: All individual components of a total door opening are required to comply with each code.

 

Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Sargent Manufacturing Company makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.

 

Door Prep: ANSI/BHMA A156.115

Door Thickness: 1-3/4" (44mm) thick door adjusts to 2" (51mm) standard, 1-3/8" (35mm) thick door, specify 1- Option for Adapter plates, Over 2" (51mm) up to 2-1/4" (57mm), specify 31- Option

Minimum Stile: 4-1/2" (114mm)

Handing: Non-handed

Backset: 2-3/4" (70mm) backset w/ 1-1/8" front (standard), 2-3/8" (60mm) backset w/ 1" wide front (specify 20- Option), 3-3/4" (95mm) backset w/ 1-1/8" front (specify 23- Option), 5" (127mm) backset w/ 1-1/8" front (specify 25- Option)

Latchbolt: Stainless steel, 1/2" (13mm) throw, Optional: Brass 3/4" (19mm) throw deadlocking fire latch for pair of doors (specify 41- Option)

Front: Wrought brass and stainless steel, 2-1/4" (57mm) x 1-1/8" (29mm) Fixed Bevel, 2-1/4" (57mm) x 1" (25mm) (included with 20- Option)

Strike: Wrought brass, bronze and stainless steel, 808 curved lip ANSI strike - standard, 800 curved lip strike (specify 29- Option), Wrought box strike available (specify WBS- Option)

Cylinder: Brass, 6-pin LA keyway, 1-bitted standard, specify KD for keyed different/random

Keys: Two nickel silver change keys per lock standard

Masterkeying: Can be master keyed or grand master keyed, Construction key systems available

Lead Lining: Lead provided between lockbody and spring cartridge (specify 74- Option)

Tactile Levers: Knurling (etching) or abrasive coating (applied finish) applied to backside of levers

 

 

Strength & Durability


  • UL Cycle above and beyond test completed at 20 Million Cycles. Verification ID: V584148
  • Exceeds 3,100 in-lb abusive locked lever torque with no entry while maintaining egress (2.6 times ANSI/BHMA A156.2 requirements)
  • Exceeds 1,600 lbs offset lever pull with no entry for protection against attacks (8 times ANSI/BHMA A156.2 requirements)
  • Latch retraction with 100lb preload (2 times ANSI/BHMA A156.2) while maintaining ANSI/BHMA requirements for operation in warped doors
  • No access with minimum 100 vertical impacts for protection against vandalism attempts (20 times ANSI/BHMA A156.2 requirements)
  • Independent return springs allow lock to exceed ANSI/BHMA A156.2 Grade 1 cycle requirements without lever sag
  • Innovative push/turn button design to withstand excessive abuse against door stops or walls.

Flexibility


  • Lock chassis design supports all cylinder formats allowing flexibility for from fixed core to interchangeable core cylinders.
  • High Security and security key systems available (Degree®, Signature, Keso, XC)
  • Patent pending adjustable push/turn button for easy door thickness adjustment.
  • Rigid lever standard; freewheeling levers available for vandal resistance.

Broad Offering


  • Available with 26 mechanical functions
  • 14 finishes and Microshield options
  • Multilple lever options including decorative and behavioral health designs

Lever & Rose Designs

10X Line Cylindrical Lever Locks

 

 

Any rose or lever on this page can be combined to suit individual taste.

All lever height measurements represent total distance from door face. Dimensions shown using L rose.

*Lever with return to within 1/2" of door face.

 

Cylinders

10X Line Cylindrical Lever Locks

 

Cylinders

• Finishes: 04, 15, BSP

All cylinders are supplied with 2 nickel silver change keys.

When cylinders are ordered keyed to 5 pin systems, the (6th) last chamber will be empty.

Cylinders are supplied 1-bitted unless specified keyed random or master keyed. For master keyed orders provide keying details as requested on SARGENT Keyed Order Lead Sheets, located in the price book or contact customer service.

To order cylinders separately, specify part number x keyway x finish (i.e. C10X-1 x LA x 15)

^Locks will be provided with the applicable tailpiece per the type interchangeable and/or removable core being used. For example standard cores and XC cores require different tailpieces. When ordering complete locks, the appropriate option code must be specified in accordance to the permanent core being used. See pages 14-15 for cylinder options.

Cylinders with Competitive Keyways

 

All cylinders are 6-pin, 0-bitted and supplied with two brass keyblanks. Cylinders include tail piece.

Refer to Cylinders and Components catalog for more information.

Interchangeable Core Tailpiece Packs (replacement parts)

Note: Tailpieces included with lock.

 

Levers That Accept Cylinders/Cores from Other Manufacturers*

*SFIC cores are available through SARGENT, all other cylinders/cores not included and are provided by others.

 

 

For more SARGENT product, click here.

For more information including price and delivery click here: https://www.idn-inc.ca/information

Or contact your local IDN-Canada branch: https://www.idn-inc.ca/store_locations


As featured in:

 

PREVIOUS POST

Schlage + Pure Access Electronic Access Control

NEXT POST

dormakaba PowerPlex 2000 Series Electronic Lock

Copyright © 1999 - 2024 All rights reserved.